Input Sample Rate

For PCM input modes, the input sample rate can be sensed and set automatically, using the Auto option, or forced. The latter is useful where use of 1 or 2 wire mode for higher sample rates might be ambiguous – otherwise Auto is best. It occurs at the bottom of the Input Sample Rate list:

Select the required entry from the list and press Set. If you have selected Auto, then the list changes when re-entered:

and the Status display will indicate that Auto is on:

Output Sample Rate

Output Sample Rate is a parameter for PCM output modes only. Select the required Output Sample Rate from the list and press Set. The dCS 974 accepts 112 input / output sample rate combinations (including DSD) in one pass. The remaining 70 combinations can be accommodated in 2 passes. These are shown in Table 2 overleaf.

Not all the apparently valid output sample rates may be available to you from

the menu. When Auto Input Sample Rate Selection is turned on, the menu system dynamically alters the Output Sample Rate menu to reflect the valid 1 pass output rates for the current input rate. For example, if Auto is turned on and the input is running at 96 kS/s, then the Output Sample Rate menu would look like this:

Manual part no: DOC1241121A1

Page 43

Document No: OS-MA-A0124-112.1A1

Contact dCS on + 44 1799 531 999

email to: more@dcsltd.co.uk

(inside the UK replace + 44 with 0)