dCS 974 User Manual

Manual for Software Version 1.0x

dCS Ltd

May 2001

 

 

Setting the Output mode

do this: Scroll down the Sample Rate Conversion menu to Output Mode and press the button. The cursor should be beside Normal Choose one of the settings from the following list, scroll to it and press Set:

 

Normal. The Output Sample Rate must not be higher than 96kS/s. Single

 

wire data will be available on all of the AES, SPDIF or SDIF-2 outputs.

 

Dual AES. The Output Sample Rate must be 88.2, 96, 176.4 or 192kS/s.

 

Dual AES data will be available on the AES 1 / AES 2 output pair and the

 

AES 3 / AES 4 output pair. Do not use the other outputs.

 

Quad AES. The Output Sample Rate must be 176.4 or 192kS/s. Quad

 

AES data will be available on the AES 1, AES 2, AES 3 and AES 4 output

 

group. Do not use the other outputs.

 

DSD SDIF-2. The input format must be DSD, DSD Quad or PCM at

 

44.1kS/s or more. DSD SDIF-2 data will be available from the DSD/SDIF

 

outputs (lower block) and DSD Quad data from the AES 1, AES 2, AES 3

 

and AES 4 output group. Do not use the other outputs.

 

DSD SDIF-3. The input format must be DSD, DSD Quad or PCM at

 

44.1kS/s or more. DSD SDIF-2 data will be available from the DSD/SDIF

 

outputs (lower block) and DSD Quad data from the AES 1, AES 2, AES 3

 

and AES 4 output group. Do not use the other outputs.

do this:

Proceed to Step 4.

Manual part no: DOC1241121A1

Page 17

Document No: OS-MA-A0124-112.1A1

Contact dCS on + 44 1799 531 999

email to: more@dcsltd.co.uk

(inside the UK replace + 44 with 0)

web site: www.dcsltd.co.uk