If you select a frequency that is more than

outputFs

, the frequency generator will

2

automatically be set to

outputFs

 

 

2 .

 

 

Select Generator: Off and press Set - it will toggle to Generator: Sine. Wait several seconds for the code to load up, then press again and it will change to Generator: Square. Press again and it will return to Generator: Off. Press Status to display the Test Mode screen:

The label appears on all status screens while the generator is on.

IMPORTANT! With the Generator On, the signal path from the selected input is disabled and replaced by the Test Generator signal.

The Generator is turned off and reset to -18.0dB, 1kHz at power down.

Self Test

The last option on the test menu is Self Test - this exercises the LEDs and the LCD display. Select this and press Set. If all is well, the LEDs will flash in sequence and the LCD will display a pattern of flashing columns. Press any button to exit from this.