Diagnostics Indicator Codes

Four diagnostic indicator lights are located behind the bezel on the I/O control panel. To access the lights, see "Opening the System" on page 43. These lights display error codes during system startup. Table 1-4 lists the causes and corrective actions associated with these codes and the power light status before system POST. Table 1-6 lists the causes and possible corrective actions for these codes during POST. A highlighted circle indicates the light is on; a non-highlighted circle indicates the light is off.

Table 1-4. Diagnostic Indicator Codes

Code

Causes

Corrective Action

No power is applied to the system.

See "Troubleshooting Power Supplies" on page 98.

A B C D

A possible processor

See "Troubleshooting the Microprocessor" on

failure has occurred.

page 109.

A B C D

 

 

 

Memory failure.

See "Troubleshooting System Memory" on

 

page 100.

A B C D

 

 

 

Possible expansion-card

See "Troubleshooting Expansion Cards" on

failure.

page 108.

A B C D

 

 

 

Possible video card

See "Troubleshooting Expansion Cards" on

failure.

page 108.

A B C D

 

 

 

Diskette or hard-drive

Ensure that the diskette drive and hard drive(s)

failure.

are properly connected. See "Hard Drives" on

A B C D

page 53 for information on the drive(s)

installed in your system.

= y e l l o w

= g r e e n

= o f f

About Your System

15

Page 15
Image 15
Dell 840 manual Diagnostics Indicator Codes