Image 32

Table 1-6. System Beep Codes

Code

Cause

Corrective Action

 

 

 

1-1-2

CPU register test failure

See "Troubleshooting the Microprocessor"

 

 

on page 114.

 

 

 

1-1-3

CMOS write/read failure;

Faulty system board. See "Getting Help"

 

faulty system board

on page 127.

 

 

 

1-1-4

BIOS error

Reflash the BIOS.

 

 

 

1-2-1

Programmable interval-timer

Faulty system board. See "Getting Help"

 

failure; faulty system board

on page 127.

 

 

 

1-2-2

DMA initialization failure

See "Troubleshooting System Memory" on

1-2-3

DMA page register write/read

page 108.

 

failure

 

1-3-1

Main-memory refresh

 

 

verification failure

 

1-3-2

No memory installed

 

1-3-3

Chip or data line failure in the

 

 

first 64 KB of main memory

 

1-3-4

Odd/even logic failure in the

 

 

first 64 KB of main memory

 

1-4-1

Address line failure in the first

 

 

64 KB of main memory

 

1-4-2

Parity failure in the first 64 KB

 

 

of main memory

 

1-4-3

Fail-safe timer test failure

 

1-4-4

Software NMI port test failure

 

2-1-1

Bit failure in the first 64 KB of

 

through

main memory

 

2-4-4

 

 

32

About Your System

Page 32
Image 32
Dell NM176 owner manual Cmos write/read failure, Faulty system board Bios error Reflash the Bios, KB of main memory