Troubleshooting the System Battery

Problem

System message indicates a problem with the battery.

System Setup program loses system configuration information.

System date and time do not remain current.

NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its system configuration information. This situation is caused by a defective battery.

Action

1Re-enter the time and date through the System Setup program. See "Using the System Setup Program" on page 35.

2Turn off the system and disconnect it from the electrical outlet for at least one hour.

3Reconnect the system to the electrical outlet and turn on the system.

4Enter the System Setup program.

If the date and time are not correct in the System Setup program, replace the battery. See "System Battery" on page 58.

If the problem is not resolved by replacing the battery, see "Getting Help" on page 127.

NOTE: Some software may cause the system time to speed up or slow down. If the system seems to operate normally except for the time kept in the System Setup program, the problem may be caused by software rather than by a defective battery.

Troubleshooting the Power Supply

Problem

System-status indicators are amber.