9On the Select Member Hard Drive screen, double-click the hard drive to select the member drive to span the array and click Next.

10For RAID 0, on the Specify Volume Size screen, select the Volume Size you want, and click Next. For RAID 1, skip to step 11.

NOTE: In the following step, you will lose all data contained on the member drive.

11Click Finish to start migrating, or click Back to make changes. You can use your computer normally during the migration process.

Rebuilding a Degraded RAID Level 1 Configuration

If your computer has reported a degraded RAID level 1 volume, contact Dell about replacing your hard drive. See "Contacting Dell" on page 150.

You can manually rebuild the computer’s redundancy mirror to a new hard drive by performing the following steps:

1Click the Start button and point to All ProgramsIntel Matrix Storage Manager Intel Matrix Storage Console to launch the Intel Storage Console.

2Right-click the available hard drive to which you want to rebuild the RAID level 1 volume, and click Rebuild to this Disk.

You can use your computer while the computer is rebuilding the RAID level 1 volume.

116

System Setup Program

Page 116
Image 116
Dell PP03X, M2010 owner manual System Setup Program