Error Code

Message Information

 

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

PCI1360

Message

A bus fatal error was detected on a component at slot

 

 

 

<number>.

 

Details

System performance may be degraded, or system may fail to

 

 

operate.

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

PST0128

Message

No memory is detected.

 

 

Details

System BIOS was unable to detect memory in the system.

 

Action

Re-seat the memory modules. If the issue persists, see

 

 

Getting Help.

PST0129

Message

Memory is detected, but is not configurable.

 

 

Details

System BIOS detected memory, but was unable to configure

 

 

the memory for system operation.

 

Action

Compare system memory installation to supported system

 

 

memory configurations.

RFM1008

Message

Failure detected on Removable Flash Media <name>.

 

 

Details

An error was reported during a SD card read or write.

 

Action

Reseat the flash media. If the problem persists, see Getting

 

 

Help.

RFM1014

Message

Removable Flash Media <name> is write protected.

 

 

Details

The card is write-protected by the physical latch on the SD

 

 

card. A write-protected card cannot be used.

 

Action

If unintended, remove the media and disable write

 

 

protection.

SEC0031

Message

The chassis is open while the power is on.

 

 

Details

The chassis is open. System performance may be degraded,

 

 

and security may be compromised.

 

Action

Close the chassis. Check system logs.

89

Page 89
Image 89
Dell R220 owner manual PCI1360 Message