You cannot use this switch in conjunction with
the -user|-u,-password|-p ,and-scope|-s switches.
-port 443|2163
Specifies the Navisphere Management
Server port number. The default is 443.
-directory outputdirectory
Specifiest hedirectory to which you want to deposit the report on the
server. This switch isrequired only if you are running the server utility
from the CD. Otherwise the report is automatically saved to the
Navisphere Server Utility installation directory.
Note: If the server utility is installed on your server and you specify a directory,
thedirectory you specify will override the server utility’s installation directory.
After uploading the HA report
In addition to running the server utility to validate server high
availability,we strongly recommend that you perform the following
manual checks.
Verifysupport of software and hardware —Makesurethatyou
haveverified that all software and hardware is supported according
to EMC’s E-Lab™ Interoperability Navigator and support matrices.
Note:Thisto
oldoes not verify that you are running supported switch
firmware, nor does it check that you are using redundant switches
(recommended).
Upgrading storage–system software— Ifyou areabout to perform
astorage-s
ystem onlinesoftware upgrade or you added an HBA, a
LUN,or changed connectivity (added a path or changed zoning):
zMake surethat you have validated all software and hardware
are supported and interoperable according to EMC E-Lab
InteroperabilityNavigator and support matrices.
zVeri fy th at all LUNs (virtual disks) that your servers will access
during the upgrade are under path management software
control. For servers running PowerPath and DMP,see the
Failover Softwaresection on the Details tab of the report and
40 EMC CLARiiON Server Support Products for Solaris Server Installation Guide