Model 3081FG

Instruction Manual

IB-106-3081 Rev. 1.5 September 2002

6

7

8

9

10

11

 

5

 

 

 

 

 

12

4

 

 

 

 

 

13

3

 

 

 

 

 

14

2

 

 

4-20 mA

15

1

 

 

16

 

 

 

 

+

 

 

 

 

 

 

MODEL 3081 TRANSMITTER

TERMINAL BLOCK

LOOP CONNECTORS

SERIAL PORT & BATTERY

LOOP CONNECTORS

USE INTERFACE

00275 0013 ONLY

 

 

CHARGER MUST

 

SERIAL PORT

 

 

NOT BE USED IN

 

 

HAZARDOUS AREAS

 

 

HART COMMUNICATOR

REAR PANEL

RL < 250

4-20 mA SIGNAL LINE

ANALOG OUTPUT DEVICE

4

250OHM

LOAD

RESISTOR (SEE NOTE)

HART COMMUNICATOR

NOTE: THE SIGNAL LOOP MUST BE BROKEN TO INSERT THE OPTIONAL 250 OHM

LOAD RESISTOR.

26020041

 

Figure 4-2. Signal Line Connections, < 250 Ohms Lead Resistance

4-3

HART COMMUNICATOR PC

b. In the on-line mode, the communicator is

 

CONNECTIONS

connected to the 4-20 mA analog output

 

 

signal line. The communicator is connected

 

There is an option to interface the HART Com-

in parallel to the Two-Wire In Situ Oxygen

 

municator with a personal computer. Load the

Analyzer or in parallel to the 250 ohm load

 

designated AMS software into the PC. Link the

resistor.

 

HART Communicator to the PC using the inter-

c. The opening menu displayed on the HART

 

face PC adapter that connects to the serial port

 

(on the communicator rear panel).

LCD is different for on-line and off-line op-

 

 

erations. When powering up a disconnected

 

Refer to the proper HART Communicator docu-

(off-line) communicator, the HART LCD will

 

mentation in regard to the PC interface option.

display the Main Menu. When powering up

 

 

a connected (on-line) communicator, the

4-4

OFF-LINE AND ON-LINE OPERATIONS

HART LCD will display the On-line Menu.

 

 

Refer to the HART Communicator manual

 

The HART Communicator can be operated both

for detailed menu information.

 

off-line and on-line.

4-5 MENU TREE FOR HART COMMUNICATOR/

 

 

 

a. Off-line operations are those in which the

TWO-WIRE IN SITU OXYGEN ANALYZER

 

communicator is not connected to the Two-

APPLICATIONS

 

Wire In Situ Oxygen Analyzer. Off-line op-

This section consists of a menu tree for the

 

erations can include interfacing the HART

 

Communicator with a PC. (Refer to applica-

HART Communicator (Figure 4-3). This menu is

 

ble HART documentation regarding

specific to Two-Wire In Situ Oxygen Analyzer

 

HART/PC applications.)

applications.

Rosemount Analytical Inc. A Division of Emerson Process Management

HART/AMS 4-3

Page 49
Image 49
Emerson 3081FG Hart Communicator PC, OFF-LINE and ON-LINE Operations, Menu Tree for Hart Communicator, Applications