ICE CONTROL SOFTWARE ICS62XX

A

ASSEMBLE PROGRAM

Format

#A,<address>(With guidance)

 

Function The mnemonic command is assembled and stored at the address indicated by <address>.

(1)Supports the mnemonics and operands in the instruction list used in the S1C62 Family.

(2)Operand expressions follow the configurations below:

p:00 to 03 values

s:00 to FF values

l:00 to FF values

i:00 to 0F values r,q: A, B, MX or MY

In general, hexadecimal expressions do not have "H" appended at the end.

Three digit data can be input starting from the 0 column.

0FF input:

Validates FF

00FF input:

Causes an error

An error is generated by invalidated values entered for p, s, l or i.

Only binary expressions (xxxxB) are allowed in the input area. The x in this case has a fixed length of from one to four digits comprised either of 0 or 1, with "B" input last.

When less than three digits are input, the expression is handled as a binary expression or an error.

(3)Either upper or lower case letters may be used for input.

(4)Mnemonic and operand codes should be separated by one or more character spaces or by a tab code.

(5)An error is generated when an unsupported instruction is entered.

(6)A or B input gains register priority. Input 0A or 0B when entering immediate value settings.

LD

A,B

Contents of B register are input to A register.

LD

B,0A

Immediate value A is loaded to B register.

VIII-38

EPSON

S1C62 FAMILY

 

 

DEVELOPMENT TOOL REFERENCE MANUAL