ICE CONTROL SOFTWARE ICS62XX

SINGLE STEP TRACE

T

Format

Function

Examples

#T,<address >,<step number> #T,<address >#T,,<step number>

#T

Executes trace, and single step actions of programs.

(1)The specified portion of the target program executes with a frequency indicated by the <step number> from the specified <address> (65535 possible in decimal code). The PC, instruction word and register contents are displayed with each execution.

(2)When the <step number> is defaulted, only one step is executed.

(3)When the <address> is defaulted, the specified number of steps is executed from the current PC (PC at which the previous T command completed).

(4)When both <address> and <step number> are defaulted, only one step is executed from the current PC. When this setting occurs after power on, one step is executed from PC=0100.

(5)When the <step number> is one (#T, <address> or #T), the instruction does not terminate after one step, but a further step is executed by the "SP" key input, at which time the instruction can be terminated by the "ESC" key input.

(6)In (1) above, the instruction is terminated by "ESC" key input.

#T,100,3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*PC=0100 IR=FFF

NOP7

 

A=0 B=0X=00F Y=00FF=IDZC SP=10
*PC=0101 IR=E05

LD

A,5A=5 B=0X=00FY=00F

F=IDZC SP=10

*PC=0102 IR=B05ADC XH,5A=5 B=0 X=051Y=00F F=IDZC SP=10

 

 

 

 

 

 

Executed PC

Command code

Correctors displayed when the flag is set

is displayed

and mnemonic

and/or reset (After executing three steps,

 

are displayed

the current PC is 0103)

#

 

 

S1C62 FAMILY

EPSON

VIII-63

DEVELOPMENT TOOL REFERENCE MANUAL