ICE CONTROL SOFTWARE ICS62XX

GO TARGET PROGRAM

G

Format

Function

#G

#G,<address >

#G,R

Display During Execution of GO Instruction

Item

Display mode (note)

 

 

Display method

1

On-the-fly display mode

#G

 

 

 

 

 

*PC=xxxx... Sampling of the PC is displayed about every 500 msec.

HALT message is displayed during halt.

2

On-the-fly inhibit mode #G

 

Exection status is not displayed.

 

Note: Refer to Section 2.3.4, "Display during run mode and during break" for information on the display modes.

Break Display

 

 

#G

 

 

 

 

 

 

 

 

 

 

*PC=xxxx

 

 

 

 

*EMULATION END STATUS = BREAK HIT... (A)

 

 

 

 

 

 

*PC=0100 A=0 B=0 X=70 Y=00 F=ID.C SP=10... (B)

 

 

 

 

 

 

*RUN TIME=xxx mS... (C)

The break status is displayed.

(A)BREAK HIT, ESC KEY, BREAK SW displays appear in parts. When the reset switch is depressed, the message, *ICE6200 RESET SW TARGET*, is displayed without displaying the break status, and the next instruction is awaited.

(B)Register contents are displayed in part when PC (next executed address) is stopped.

(C)The execution time or executed number of steps set by TIM command are displayed in part. (Refer to the TIM command.)

S1C62 FAMILY

EPSON

VIII-61