ICE CONTROL SOFTWARE ICS62XX

FILL DATA RAM

FD

Format

Function

#FD,<address 1>,<address 2>,<data>

<data> is stacked in the data RAM area at <address 1> to <address 2> in hexadecimal or binary code.

Data RAM area (for S1C6S3N7/6S3B7/6S3L7)

00

Address 1 . . . 06

Address 2 . . . 40

70

Data

 

 

Reloads with specified data

 

 

 

 

LCD RAM

7E

I/O

 

 

 

 

 

 

 

 

 

 

Examples #FD,60,7E,A

 

 

 

 

 

... Reloads the contents of the data RAM addresses 60 to 7E to A

 

 

 

#FD,10,2F,0101B

 

...

Reloads address 10 to 2F with data 0101 (binary) = 5 (hexadecimal)

 

 

 

#FD,50,1FF,0

 

 

...

Error is generated because settings exceed the RAM area

 

 

*COMMAND ERROR * (address 7E for S1CS1C6S3N7/6S3B7/6S3L7) and the instruction will not execute

#FD,70,60,0

*COMMAND ERROR * ... Address 1 > address 2 error

 

#FD,0,7E,B

 

 

... Reloads the entire RAM area (for S1C6S3N7/6S3B7/6S3L7)

 

 

 

 

 

 

 

 

 

with data B (hexadecimal)

 

#FD,40,40,0

 

... 0 written to 40 address

 

 

 

 

 

#

 

 

 

Notes

 

 

(1) For binary expressions, four digit 0 (or 1) and B input (total of five characters) only are

 

 

 

accepted.

 

 

(2)Write operation is not performed to the read only address of the I/O area.

(3)When there is an unused area in the specified address, the data is rewritten except for the unused area.

S1C62 FAMILY

EPSON

VIII-41

DEVELOPMENT TOOL REFERENCE MANUAL