ICE CONTROL SOFTWARE ICS62XX

SP

SET PROGRAM

Format

#SP,<address>

(With guidance)

 

Function Contents of the specified program area <address> are displayed or modified.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Examples #SP,100

 

 

 

 

 

 

 

 

... Contents of address 100 are read, and cannot be modified

 

 

0100

FFF:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

by a

 

alone

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0101

FFF:FFB

 

 

...

New data is written

 

 

0102

FFF:FF9

 

 

... Error message is displayed when undefined code is

 

 

 

 

* CODE ERROR *

 

 

 

 

 

 

 

 

 

 

 

 

 

detected; contents are written unchanged to the same

 

 

 

 

 

 

 

 

 

 

 

 

 

address

0102

FFF:F05

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0103

FFF:A6B

 

 

... Operation returns to previous address (one less than

 

 

0104

FFF:^

 

 

 

 

0103

A6B:^

 

 

 

current address) via input by entering ^

 

 

 

 

 

 

 

 

0102

F05:F06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0103

A6B:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0104

FFF:ABx

 

 

... Error is generated by data setting error; message displayed

 

 

 

 

* COMMAND ERROR *

0104

FFF:ABC

 

 

 

/

 

input terminates instruction

 

 

 

 

 

 

0105

FFF:/

 

 

...

 

 

 

 

 

#SP,400

*COMMAND ERROR * ... Since it exceeds the program area (3FF for S1C6S3N7/ 6S3B7/6S3L7), an error is indicated

#SP,3FE
3FEFFF:011

 

... Instruction is completed after last address in input

 

 

3FF

FFF:FFB

 

 

 

#

VIII-44

EPSON

S1C62 FAMILY

 

 

DEVELOPMENT TOOL REFERENCE MANUAL