FUNCTION OPTION GENERATOR FOG62XX

4.5 HEX File Generation and EPROM Selection

When setting function options setting is completed, the following message is output to ask the operator whether to generate the HEX file.

END OF

OPTION SETTING.

 

. . (1)

DO YOU

MAKE HEX FILE (Y/N) ? Y

 

 

 

*** OPTION EPROM SELECT MENU ***

1.27C64

2.27C128

3.27C256

4.27C512

PLEASE SELECT NO.? 2

 

 

. . (2)

 

2. 27C128

SELECTED

When debugging the program with evaluation board, HEX file C2XXYYYF.HEX is needed.

Note The EPROM to be mounted on the evaluation board must satisfy the following conditions:

EPROM for setting function options: Tacc 250 ns

(Tacc: Access time)

(1)DO YOU MAKE HEX FILE (Y/N)?

When debugging the program with evaluation board, HEX file C2XXYYYF.HEX is needed, so enter "Y". If "N" is entered, no HEX files are generated and only document files C2XXYYYF.DOC is generated.

(2)PLEASE SELECT NO.?

For the option ROM selection menu displayed when "Y" is entered in Step (1), select the EPROM to be used for setting evaluation board options. This menu is not displayed when "N" is entered in Step (1). One EPROM is required for setting function options (27C128 is selected in the above example).

When the above operation is completed,

FOG62XX generates files. If no error is committed

MAKING FILE(S) IS COMPLETED.while setting segment options, the following message is output and the sequence returns to the operation selection menu.

4.6 End Procedure

This section explains how to end FOG62XX execution.

*** OPERATION SELECT MENU ***

1.INPUT NEW FILE

2.EDIT FILE

3.RETURN TO DOS

PLEASE SELECT NO.? 3

A>

When a series of operations are complete, the sequence returns to the operation selection menu. Execution of FOG62XX can be ended by selecting "3. RETURN TO DOS" on this menu. If "1. INPUT NEW FILE" or

"2. EDIT FILE" is selected, setting function options can be performed again.

FOG62XX can be forcibly terminated by pressing the "CTRL" and "C" keys together during program execution. (It is possible by pressing "STOP" key depending on the PC used.)

S1C62 FAMILY

EPSON

V-7

DEVELOPMENT TOOL REFERENCE MANUAL