6 TROUBLESHOOTING

Tool

Problem

 

Remedy measures

ICE

Nothing appears on the screen, or

Check the following and remedy if necessary:

S5U1C62000H nothing works, after activation.

• Is the RS-232C cable connected correctly?

 

 

• Is the RS-232C driver installed?

 

 

• Is MODE.COM on the disk?

 

 

• Is the execution file correct?

 

 

PC-DOS

ICS62XXW.EXE

 

 

• Is the DOS version correct?

 

 

PC-DOS

Ver. 2.1 or later

Is the DIP switches that set the baud rate of the main ICE unit set correctly?

Is the fuse of the ICE cut off?

 

The ICE fuse cut immediately after

Check the following and remedy if necessary:

 

activation.

• Are connectors F1 and F5 connected to the evaluation

 

 

board correctly?

 

 

 

 

• Is the target board power short-circuiting?

 

 

 

 

<ILLEGAL VERSION ICE6200>

The wrong version of ICE is being used. Use the latest

 

appears on the screen immediately after

version.

 

 

 

activation.

 

 

 

 

 

 

 

<ILLEGAL VERSION PARAMETER

The wrong version of ICS62XXP.PAR is being used. Use

 

FILE> appears on the screen immedi-

the latest version.

 

 

 

ately after activation.

 

 

 

 

 

 

 

Immediate values A (10) and B (11)

The A and B registers are reserved for the entry of A and B.

 

cannot be entered correctly with the A

Write 0A and 0B when entering A (10) and B (11).

 

command.

Example: LD

A, B

Data in the B register is

 

 

 

 

loaded into the A register.

 

 

LD

B, 0A

Immediate value A is loaded

 

 

 

 

into the B register.

 

 

 

 

<UNUSED AREA> is displayed by the

This massage is output when the address following one in

 

SD command.

which data is written is unused. It does not indicates

 

 

problem. Data is correctly set in areas other than the read-

 

 

only area.

 

 

 

 

 

 

You can not do a real-time run in

Since the CPU stops temporarily when breaking conditions

 

break-trace mode.

are met, executing in a real-time is not performed.

 

 

 

 

Output from the evaluation board is

Output is possible only in the real-time run mode.

 

impossible when data is written to the I/

 

 

 

 

O memory for Buzzer and Fout output

 

 

 

 

with the ICE command.

 

 

 

 

 

 

SOG62XX An R error occurs although the address

Check the following and remedy if necessary:

 

is correctly set in the segment source

• Does the address symbol use capital letters?

 

file.

• Are the output ports set for every two terminals?