INTRODUCTION

Tool

Problem

 

Remedy measures

ASM62XX

An R error occurs although the final

The cross assembler is designed to output "R error" every

 

page is passed.

time the page is changed. Use a pseudo-instruction to set the

 

 

memory, such as ORG or PAGE, to change the page. See

 

 

"Memory setting pseudo-instructions" in the cross assem-

 

 

bler manual.

 

 

 

MDC62XX

Activation is impossible.

Check the following and remedy if necessary:

 

 

• Is the number of files set at ten or more in OS environ-

 

 

 

ment file CONFIG.SYS?

 

 

 

MLA628X

No melody is output.

Check the following and remedy if necessary:

 

 

• Has the OPTLD command of the ICE been executed? (When

 

 

 

the ICE is connected to the evaluation board)

 

 

Is the MELODY ROM installed? (When the evaluation

 

 

 

board is used independently)

 

 

• Is the attack bit of the melody data set to "1"?

 

 

 

Evaluation

The evaluation board does not work

Check the following and remedy if necessary:

board

when it is used independently.

Has the EPROM for F.HEX and S.HEX been replaced by

S5U1C62xxxE

 

 

the EPROM for the target?

 

 

Is the EPROM for F.HEX and S.HEX installed correctly?

 

 

• Is the appropriate voltage being supplied? (5V DC, 3 A,

 

 

 

or more)

 

 

Are the program ROMs (H and L) installed correctly?

 

 

Is data written from address 4000H? (When the 27C256

 

 

 

is used as the program ROM)

 

 

Is the EN/DIS switch on the evaluation board set to EN?

 

 

 

 

Target segment does not light.

Check the following and remedy if necessary:

 

 

Is an EPROM with an access time of 170 ns or less being

 

 

 

used for S.HEX.

 

 

Has the VADJ VR inside the evaluation board top cover

 

 

 

been turned to a lower setting?

 

 

 

 

S1C62 FAMILY

EPSON

I-7

DEVELOPMENT TOOL REFERENCE MANUAL