ICE CONTROL SOFTWARE ICS62XX

FP

FILL PROGRAM

Format

Function

#FP,<address 1>,<address 2>,<program data>

Data <program data> is stacked in the program area (ICE emulation memory) at <address 1> to <address 2>.

Program area (for S1C6S3N7/6S3B7/6S3L7)

000

Address 1 . . . 100

Program data

Reloads with specified data

Address 2 . . . 2FF

3FF

 

 

 

 

 

 

 

 

Data from addresses 000 to 3FF of the program area

Examples #FP,0,3FF,FFB

 

 

 

 

...

 

 

 

 

 

 

 

 

 

 

are stacked to the FFB (NOP5 code)

 

 

#FP,100,200,FF9

 

 

...

When undefined code is detected, an error message is

 

 

 

 

* COMMAND ERROR *

 

displayed and the instruction will not execute

#FP,200,100,FFF

*COMMAND ERROR * ... Address 1 > address 2 error

#FP,200,200,FFF

 

... Address 200 is modified to instruction code FFF (NOP7);

 

 

 

 

instruction completes normally

#

VIII-40