ICE CONTROL SOFTWARE ICS62XX

SET DATA RAM

SD

Format

Function

#SD,<address>

(With guidance)

Contents of the data RAM area <address> are displayed or modified.

(1)Data cannot be written to the read only area.

(2)Data in the write only area cannot be read.

 

 

 

 

 

 

 

 

 

 

Examples #SD,20

 

... Contents of address 20 are modified and stored to A

 

 

20

5:A

 

 

 

21

5:^

 

... Return to previous address (one less than the current

 

 

20

A:B

 

address) by entering ^

 

 

 

 

 

 

 

 

21

5:F

 

... Instruction terminated by /

 

 

 

 

 

 

 

 

22

5:/

 

 

 

 

 

 

 

#SD,FFF

*COMMAND ERROR * ... When specification exceeds the maximum value of the

 

 

 

RAM area (7F for S1C6S3N7/66S3B7/6S3L7), an

 

 

 

error is indicated

#SD,70

 

 

 

 

 

 

70

4:-

 

... Hyphen only displayed due to read only address;

 

 

71

F:-

 

 

 

72

5:-

 

data input not accepted

 

 

736:-746:5758:4765:A778:9788:579A:- 7A B:-

: : :

7E F:-

 

 

 

 

... Command terminates after last address entered

 

 

#SD,E50

 

 

 

 

... When an unused area has been specified, "UNUSED

 

 

* UNUSED AREA *

 

 

 

 

 

AREA" is displayed (for S1C6S460)

#SD,ECE

 

 

 

 

 

 

 

 

 

ECE 0:F

 

 

 

 

 

 

 

ECF 4:F

 

 

... When an unused area is entered into during data setting,

 

 

* UNUSED AREA *

 

 

 

 

 

"UNUSED AREA" is displayed (for S1C6S460)

S1C62 FAMILY

EPSON

VIII-45

DEVELOPMENT TOOL REFERENCE MANUAL