ICE CONTROL SOFTWARE ICS62XX

DP

DUMP PROGRAM

Format

Function

#DP,<address 1>,<address 2>#DP,<address 1>#DP

The program area (emulation program memory) from <address 1> to <address 2> is displayed in hexadecimal format.

(1)When <address 2> defaults, the contents of <address 1> are displayed in a single screen (21 lines, 21⋅ 8=168 addresses).

(2)When <address 1> and <address 2> default, a single screen is displayed from the previous address plus one (one more than the previous address).

When DP alone is entered after power on, the data from address 0 are displayed.

(3)When more than one screen of data is displayed, a one line space appears between every 21 lines with about a one second pause.

(4)Hexadecimal and ASCII codes can be displayed together, but the ASCII data operands are converted by the RETD and LBPX instructions before display.

Example:

Data content 142 ... ASCII display B

 

(Instruction: RETD 42)

(5)When the last program area passes, the operation terminates.

(6)Commands can be interrupted by input from the "ESC" key.

Program area (for S1C6S3N7/6S3B7/6S3L7)

000

Address 1 . . . 100

Program data from this area are displayed.

Address 2 . . . 2FF

3FF

VIII-22

EPSON

S1C62 FAMILY

 

 

DEVELOPMENT TOOL REFERENCE MANUAL