Specifications
Electrical Specifications
Nominal input network voltage | 15 | Vdc |
Maximum operating current | 200 mA @ nominal | |
| input network voltage | |
|
|
|
Relay contact voltage rating | 12 | Vdc, 30 Vdc max.* |
|
| |
Maximum relay contact current | 5 A DC* | |
|
|
|
Nominal 12/24 V thermostat input voltage | 12 | Vdc/24 Vdc* = On |
|
| |
Minimum 12/24 V thermostat input voltage | 9.5 Vdc* | |
|
|
|
Maximum 12/24 V thermostat input voltage | 30 | Vdc* |
|
| |
Typical 12/24 V thermostat input current | 14.6 mA @ 12 V | |
|
|
|
Nominal 12/24 V generator running B+ voltage | 12 | Vdc/24 Vdc*= On |
|
| |
Minimum 12/24 V generator running B+ voltage | 9.5 Vdc* | |
|
|
|
Maximum 12/24 V generator running B+ voltage | 30 | Vdc* |
|
| |
Typical 12/24 V generator running B+ current | 14.6 mA @ 12 V | |
|
| |
Communication physical layer | 2, CAN | |
|
| |
Communication protocol | Xanbus | |
|
| |
Maximum cable length | 130 ft. (40 m) | |
|
|
|
*Limited to Class 2 levels (100 VA) as in Chapter 2, page