System Requirements

System Requirements

 

Minimum basic system components include the following.

 

An XW Inverter/Charger

 

An AC Generator or DC Generator

 

An XW System Control Panel

 

An XW Automatic Generator Start

Network

The XW Auto Generator Start uses Xanbus™, a network communications

Communication

protocol developed by Xantrex, to communicate its settings and activity

Protocol

to other Xanbus-enabled devices. All network components used in the

 

system must be Xanbus-enabled.

Network Power

The XW Auto Generator Start requires 3 watts of power (maximum) to

Supply

operate. This power supply is provided by the XW Inverter/Charger

 

through the Xanbus network.

Generator

The generator should be a 2-wire or 3-wire generator with Auto Start

 

capability.

 

The generator should also supply a Generator Run signal. This signal is

 

used by the XW Auto Generator Start to detect whether the generator is

 

running. Some generator manufacturers refer to this signal as the Hour

 

Meter Signal or Switched B+.

Generator

The XW Auto Generator Start supports most two and three-wire

Compatibility

generator starters. Some manufacturers include, but are not limited to,

 

Onan (Quiet Diesel, gasoline, and LP), Power Tech, Generac, Northern

 

Lights, Fisher Panda, Westerbeke, Kohler, Honda, and Yamaha. Check

 

with the generator manufacturer to ensure the generator in question

 

includes automatic starting capabilities.

XW System

A XW System Control Panel is required to configure the XW Auto

Control Panel

Generator Start and monitor generator starting and stopping activity.

 

The XW System Control Panel also provides real-time clock information

 

for the XW Auto Generator Start Quiet Time and Exercise Time features.