Installation
Table 2-19 Wiring for Connecting an External Manual ON/OFF Switch
|
| Wiring Harness Wire |
Wire Number | Function | Color |
|
|
|
7 | External manual on input | White/Green |
|
|
|
8 | External manual off input | White/Red |
|
|
|
9 | External On/Off LED Indicator output | White/Blue |
|
|
|
10 | Constant 12/24 V B+ for External On/ | Red |
| Off/LED Indicator |
|
|
|
|
11 | External On/Off/LED Indicator return | Black |
|
|
|
Multiple generator control panels or simple contact closures can be wired to the external manual ON/OFF inputs. The XW Auto Generator Start detects if any of the contacts close and will change its operating mode to External Manual On or External Manual Off (for more information, see “GenMode” on page
The External Manual On and External Manual Off states are not affected by maximum generator run time (see “Max Run Time” on page
Connecting an External ON/OFF LED
Wires 9 (White/Blue) and 11 (Black) on the wiring harness can be connected to an LED or other light to accompany a remote external ON/ OFF switch. This light turns on when the generator run signal is active to visually indicate that the generator is running.
Important: With some generators, the generator run signal becomes active during the preheat stage, before the generator is actually running. In this case, the external ON/OFF LED (and the Generator On light on the XW Auto Generator Start) will turn on during the preheat stage and remain on when the generator is running.
For some generators, these lights will also remain on for a period of time after the generator has stopped.