Xantrex Technology XW manual User Settings, Values, Default

Models: XW

1 124
Download 124 pages 55.26 Kb
Page 82
Image 82
User Settings

Configuration

User Settings

Use this table to record any customized XW Auto Generator Start settings for future reference.

Table 3-3Generator Configuration Settings, Values, Defaults, and User Settings

 

 

 

 

User

Setting

 

Values

Default

Setting

 

 

 

 

 

Main Menu Items:

 

 

 

 

 

 

 

GenMode

 

ManualOn, ManualOff, Automatic

ManualOff

 

 

 

 

 

 

Mode

 

Operating/Standby

Operating

 

 

 

 

 

Configuration Menu Items:

 

 

 

 

 

 

“QT En”

 

Enabled, Off

Enabled

 

 

 

 

 

 

“QT Begin”

 

12:00AM–11:59PM (12-hour clock)

9:00PM (12-hour clock)

 

 

 

00:00–23:59 (24-hour clock)

21:00 (24-hour clock)

 

 

 

 

 

 

“QT End”

 

12:00AM–11:59PM (12-hour clock)

8:00AM (12-hour clock)

 

 

 

00:00–23:59 (24-hour clock)

8:00 (24-hour clock)

 

 

 

 

 

 

“Gen Type”

 

Type 1 to Type 13

Type 2

 

 

 

 

 

 

Triggers Menu Items:

 

 

 

 

 

 

 

“Start DCV 30 sec”

 

Disabled, 4.0 V–65.0 V

44.0 V

 

 

 

 

 

 

“Start DCV 15 min”

 

Disabled, 4.0 V–65.0 V

Disabled

 

 

 

 

 

 

“Start DCV 2 hr”

 

Disabled, 4.0 V–65.0 V

Disabled

 

 

 

 

 

 

“Start DCV 24 hr”

 

Disabled, 4.0 V–65.0 V

Disabled

 

 

 

 

 

 

“Stop Float”

 

Enabled, Disabled

Disabled

 

 

 

 

 

 

“Stop Absorb”

 

Enabled, Disabled

Enabled

 

 

 

 

 

 

“Stop V”

 

Disabled, 4.0 V–65.0 V

Disabled

 

 

 

 

 

 

“Temp1”

 

Enabled, Disabled

Disabled

 

 

 

 

 

 

“Temp2”

 

Enabled, Disabled

Disabled

 

 

 

 

 

 

“Load”

 

Enabled, Disabled

Disabled

 

 

 

 

 

 

“Start Load”

 

10.0 A–33.0 A

10.0 A

 

 

 

 

 

 

“Stop Load”

 

7.0 A–28.0 A

7.0 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3–32

975-0307-01-01

Page 82
Image 82
Xantrex Technology XW manual User Settings, Values, Default