5 Menu Configuration
The LRP2000 features a
5.1 How to Enter the Menu Configuration
Begin by connecting the COM2 port to your PC host (see table below) and running EC that is available on the diskette, or from Escort Memory Systems’ Web site at
LRP2000 |
| Standard PC Serial Port | |
|
|
|
|
COM2 Pin Number | Signal Name | DB9 Pin Number | Signal Name |
|
|
|
|
5 | TX | 2 | RX |
|
|
|
|
4 | RX | 3 | TX |
|
|
|
|
6 | GND | 5 | GND |
|
|
|
|
Set the serial parameters to the LRP2000 default settings or the last known state of COM2. The default settings for COM2 are as follows:
•Baud- 9600
•Parity- None
•Data bits- 8
•Stop bits- 1
•Flow control- None
If you cannot establish communications with COM2, do the following to restore the default values:
1.Place DIP switch 5 in the ON position and cycle power to the LRP2000, or press the reset switch. This loads the default values.
2.Place DIP switch 5 in the OFF position and cycle power once more.
Please refer to Chapter 4, Communications Interface for more information on the serial interface.
To enter the Main Board Configuration Menu, cycle power or press the reset switch, and then press CTRL- D within the first seven seconds of the initialization. The LRP2000 displays the Configuration Menu. As the LRP2000 starts the Configuration program, both the RF and CONFIG LEDs flash. The Main Board Configuration Menu displays with the current main board software version number together with the DSP firmware version.
*****************************************************
LRP2000 (ISO Only) Standard Program Main Program V0.5D, Sept. 2002 DSP Program V0.5c, November 2002
*******************************************************
[1]
[2]Download New Program
[3]Download DSP Program
[4]Exit to Operating Mode Enter Selection: