Menu Configuration
5.2 Set-Up Operating Parameters
To change the operating parameters of the LRP2000, enter 1 at the initial menu.
The following menu is displayed, listing the current settings (the exact appearance of the menu display depends on the settings you have made and will be updated when you save your changes):
Serial Port COM1: RS232, 9600, N, 8, 1, No handshake (DIP switches)
Serial Port COM2: RS232, 9600, N, 8, 1, No handshake
Command Protocol: ABx Standard
RF Communication: Fast Mode
[1]Set COM1 Parameters
[2]Set COM2 Parameters
[3]Set Operating Mode
[4]Set RF Communications
[5]Restore Factory Defaults
[6]Return to Main Menu Enter Selection:
Enter the number of the
The following
5.2.1 Set COM1 Parameters
Selecting 1 from the above menu displays the following options for the COM1 parameters. These settings are valid only if you are not using the DeviceNet Interfaces (such as DIP switch 4 is in the OFF position). Enter the appropriate number at each prompt. The default values are indicated by an asterisk (*).
*** Set COM1 Parameters ***
Baud Rate? [0] 1200 [1] 2400 [2] 4800 [3] 9600* [4] 19200 [5] 38400 Data size? [0] 7 bit [1] 8 bit*
Parity? [0] None* [1] Even [2] Odd
Handshake? [0] None* [1] Xon/Xoff
Save Changes to EEPROM? [0] No [1] Yes
5.2.2 Set COM2 Parameters
Selecting 2 from the “[1]
*** Set COM2 Parameters ***
Baud Rate? [0] 1200 [1] 2400 [2] 4800 [3] 9600* [4] 19200 Data size? [0] 7 bit [1] 8 bit*
Parity? [0] None* [1] Even [2] Odd
Handshake? [0] None* [1] Xon/Xoff
Save Changes to EEPROM? [0] No [1] Yes
LRP2000 Passive Reader/Writer | 48 |