RFID Communications

6.4.18 ABxS Command 8CH: Lock Family Code All

DESCRIPTION

Command 8CH locks the family codes of tags in the field. Once locked, the family codes cannot be changed or unlocked.

DISCUSSION

The command must pass a family code to select the tags whose family code will be locked. The controller returns a response when the timeout period expires. The parameter of the response in the number of tags written.

The command is formatted as shown below:

Field

Remarks

Command

Command number in hex preceded by AAH

 

 

Family Code

Family Code, 00H = all tags

 

 

Reserved

00H

 

 

Timeout

Timeout value given in 1 ms units (001EH - FFFEH)

 

 

Message Terminator

FFFFH

 

 

Example

This example locks the family code on all tags with the family code 02H. Two tags are found and locked.

Command from Host

MSB

LSB

Remarks

AAH

8CH

Perform Command 8CH

 

 

 

02H

00H

Family ID/Reserved

 

 

 

07H

D0H

2 second Timeout

 

 

 

FFH

FFH

Message Terminator

 

 

 

Response from Controller

MSB

LSB

Remarks

AAH

8CH

Command Echo

 

 

 

02H

08H

Ntags/Status

 

 

 

FFH

FFH

Message Terminator

 

 

 

79

LRP2000 Passive Reader/Writer

Page 84
Image 84
Escort LRP2000 manual ABxS Command 8CH Lock Family Code All, AAH 8CH