Templates

Use the rough-in templates in this appendix as guides to measure and mark the hole in the wall or furniture through which the MLC 52 will be mounted. The templates provide measurements for installing the controller with either an electrical box or a mounting bracket. (You do not need the templates if you are mounting the panel using an external mounting option.)

The templates are not to scale and are provided for reference only.

The MLC controller requires a depth of at least 1.25" (3.2 cm) inside the wall or furniture.

If you use a wall box or mud ring, connect it to an earth ground. If you do not use a grounded wall box or mud ring, ground the faceplate to an earth ground, or tie it to the circuit ground via a ground pin on the circuit board.

MLC 52 IR and MLC 52 RS Template

4.50"

(11.43 cm)

Cut-Out Template for Extron's

MLC 52

(Front View)

2.79"

(7.09 cm)

1.9" (4.83 cm)

2.91" (7.40 cm)

SURFACE

CUT-OUT AREA

FOR

FURNITURE

MOUNT

Top Panel

Location of MLC 52

To install an MLC 52 faceplate directly into furniture or wall, cut along this line.

MLC 52 IR and MLC 52 RS cutout template

B-2 MLC 52 Series MediaLink Controllers • Templates

Page 120
Image 120
Extron electronic manual MLC 52 IR and MLC 52 RS Template, MLC 52 IR and MLC 52 RS cutout template