Projector remote control type B (application 3)

This remote control has only two input buttons — one for the RGB inputs and one for the S-video and composite video inputs. Each of these buttons contains two commands (commands “A” and “B”) that cause the button to toggle between inputs.

Following these steps, use IR learning to program the input selection commands from the projector’s type B hand-held remote control onto the MLC’s PC and Video or blank (VC models) buttons.

Programming RGB inputs — projector remote control type B

1.Place the rear panel configuration DIP switch #1 in the On (up) position to enter learning mode.

ON

1 2 3 4

2. Using IR learning, program command “A” from the RGB input selection button on the projector’s remote control into memory block #1 of the MLC 52’s PC button as follows:

a. Press the PC button on the MLC front panel. The button blinks, indicating that the MLC is ready to learn the command. On the rear panel, the bottom IR learning LED flashes.

b. Within 5 seconds (while the PC button on the MLC 52 is blinking), press the RGB button on the projector’s remote control. The MLC has learned command “A” for RGB.

When a command has been successfully learned, the IR learning LEDs on the MLC rear panel flash in rapid progression from the top to the bottom, then back to the top.

3. Program the input selection command “B” from the RGB input selection button on the projector’s remote control into memory block #2 of the MLC 52’s PC button as follows:

a. Press the PC button on the MLC front panel. The button blinks, indicating that the MLC is ready to learn the command. On the rear panel, the second LED from the bottom flashes.

b. Within 5 seconds (while the PC button on the MLC 52 is blinking), press the RGB button on the projector’s remote control. The MLC has learned command “B” for RGB.

4. If finished programming the MLC 52 buttons, return configuration DIP switch #1 to its Off (down) position, and test the system.

If you want to program video input selection at this time, proceed to “Programming video inputs — type B remote control,” on the next page.

MLC 52 Series MediaLink Controllers • Special Applications 4-13