
Installation, cont’d
4. | Lift out the transparent square label that you want to replace, being careful |
| not to damage the circuits beneath it. You may need to use the small |
| screwdriver to gently pry the label out. |
5. | Detach one of the preprinted labels or one of the blank labels from the label |
| sheets included with the MLC 52. Remove the label from the backing and, if |
| applicable, peel the protective film from the front of the label. |
If you want to create customized labels, you can use a label maker, such as the Brother®
6.Insert the new label into the clear button cap, align the white backing plate with the cap, and firmly snap it into place.
7.Gently, but firmly, press the reassembled button into place on the MLC 52 front panel.
8.Repeat steps 1 through 7 as needed to relabel other buttons.
Mounting an electrical box
If you want to install the MLC 52 in an electrical box (in a wall or in furniture),
1.Refer to the appropriate template diagram in appendix B, “Dimensions and Templates,” to find out the dimensions of the opening required for the size of the wall box that you are using. If you are using a mud ring with the wall box, refer to the templates provided with the bracket.
2.Using a ruler or tape measure and a soft pencil, draw guidelines on the installation surface (wall or furniture) in the desired orientation and location where the opening for the bracket or wall box will be cut.
CAUTION
The template diagrams in this guide are not to scale. Do not trace them or use them as patterns on the installation surface. Use these diagrams only for reference to obtain the dimensions of the hole that needs to be cut. Use a ruler to measure and draw the cutting guidelines.
3.Cut out the wall or furniture material inside the marked area.
4.Check the opening size by inserting the wall box or mounting bracket into the opening. The equipment should fit easily into the opening. Enlarge or smooth the edges of the opening if needed.
5.Feed cables through the wall box
6.Exposed cable shields (braids or foil) are potential sources of short circuits. Trim back and/or insulate shields with heat shrink.
To prevent short circuits, you can cut back the outer foil shield to the point where the cable exits the cable clamp. Both braided and foil shields should be connected to an equipment ground at the other end of the cable.
7.Insert the wall box into the opening, and attach it to the wall stud or furniture with nails or screws, leaving the front edge flush with the outer wall or furniture surface. The following illustration applies to all sizes of wall boxes.