UL Requirements
The Underwriters Laboratories (UL) requirements listed below pertain to the installation of the MLC into a wall or furniture.
1.Elevated operating ambient temperature — If the equipment is installed in a closed or multiunit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consider installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. For the MLC 52, the Tma is 122 °F (50 °C).
2.Reduced air flow — Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
3.Mechanical loading — Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
4.Circuit overloading — Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
5.Reliable earthing (grounding) — Reliable earthing of
Installation Procedures
The MLC 52 can be installed into a wall or furniture. Follow the instructions appropriate to the mounting option you have selected.
Preparing the site and installing the wall box
The installation of the MLC 52 must conform to national and local electrical codes and to the equipment’s size requirements.
Installation using a UL listed wall box is recommended for most mounting options, but mounting brackets can be used instead. To mount the controller using an electrical box and/or a mounting bracket, use one of the
The templates are not to scale and are provided for reference only.
•The MLC 52 models include a
•The MLC 52 VC models have
•Also available are optional faceplates that accept the MLC 52 and can be installed into