Operation, cont’d

+ 12V

GND

IR IN

GND

IR OUT

Tx

 

4

3

2

1

1

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

ON

3

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

E

 

ON

1 2 3 4

Transmitting MLC

Less Than 6”

IR Beaming

E

4

 

3

 

ON

 

 

 

 

2

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

IR OUT

 

1

2

3

4

 

Tx

GND

IR IN

GND

+ 12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

1 2 3 4

Receiving MLC

Setting up transmitting and receiving units for wireless data transfer

The data transfer begins when the receiving unit detects the transmitting unit, and the process takes 15 to 20 seconds to complete. (It may take longer if the transmitting unit has multiple commands programmed on each button.)

The front panel buttons act as data transfer progress indicators. While data is being transferred, the buttons on both the transmitting and the receiving MLCs blink sequentially in clockwise order, starting with the On button in the upper-left corner (see the diagram below). This cycle repeats until transfer is complete.