Operation, cont’d

Wiring and connections for the MLC 52 VC models

Connect the cables to the MLC 52 IR VC or MLC 52 RS VC controller with the MPA Series amplifier as shown in the diagram below and on page 2-15.

RS-232 or IR Projector Control

 

E

 

 

 

 

 

 

4

 

 

 

 

 

 

3

ON

 

 

 

 

2

 

 

 

 

 

 

1

1

2

3

4

 

Tx

IR OUT

GND

IR IN

GND

+ 12V

VOL/

MUTE

+ 10V

MLC 52 VC Series

COMPUTER

IN-1

Y/C

VIDEO

AUDIO

 

 

 

PC

 

 

 

COMPUTER

IN-2

 

 

AUDIO

 

AUDIO

 

R

 

L

Y

G

H/Cs

R

PB/B-Y

B

V

 

PR/R-Y

COMPUTER

CONTROL

 

OUT

 

 

 

 

 

REMOTE

AUDIO OUT

AV IN

INPUTS

 

MPA 122

C

US

OUTPUTS

 

 

4/8 Ohms

POWER

L

 

 

 

 

 

 

REMOTE

 

 

 

 

 

 

 

 

R

R

10V

L

R

12V

L

3A MAX

 

 

VOL/MUTE

 

 

 

MPA 122

 

RS-232

Projector

To Loudspeakers

Any input on the MPA

 

 

can be used.

Wiring an MLC 52 VC controller and an MPA series power amplifier to a typical projector

Audio is now controlled from the MPA instead of from the projector. For best results, ensure that the audio volume of the projector is set to maximum (assuming that the monitor output for audio is variable).

Configuring the MLC 52 IR and MLC 52 RS Vol buttons

By default, the MLC 52 has two buttons on the front panel programmed for volume control (Vol > and Vol <). However, on the MLC 52 IR and RS VC models, these buttons are not needed for volume control and can be programmed for other uses. To reprogram the Vol buttons, you can use IR learning (see “Configuring using IR learning,” earlier in this chapter,) or the Windows-based configuration software (see chapter 5, “Serial Communication”).

Powering the Display Device On and Off

The Display On and Off buttons on the MLC 52 front panel are used to turn the projector or other display on and off.

Powering on

Press and release the MLC 52’s On button to turn the display device’s power on. The MLC sends an RS-232 or IR power-on command to the projector, and the On button blinks for 4 seconds, then remains steadily lit.

3-12 MLC 52 Series MediaLink Controllers • Operation

Page 40
Image 40
Extron electronic Powering the Display Device On and Off, Wiring and connections for the MLC 52 VC models, Powering on