Reference Information

Configuring the MVP 104GX for RS-422

The MVP 104GX comes configured from the factory for RS-232 communications. If an RS-422 configuration is required, follow the procedures below. The procedures involve removing the top cover, relocating the serial port ribbon cable, setting the jumper, and replacing the top cover.

Removing the top cover

The top cover of the MVP 104GX must first be removed to gain access to the ribbon cable and jumper.

1. Disconnect the power cord from the MVP 104GX.

2. If the MVP 104GX is rack mounted, remove the MVP from the rack.

3. Remove the fourteen screws which secure the top cover of the MVP 104GX, as shown in figure A-1.

Lift Cover straight up

 

 

 

 

 

 

 

UT

4

 

 

 

 

 

 

 

INP

 

 

 

 

 

 

UT

3

 

 

 

 

 

 

 

INP

 

 

 

 

 

IN

 

UT

2

 

IN

 

 

OU

T

INP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

 

 

OU

T

 

 

 

 

 

 

 

 

 

 

 

 

 

UT

1

INP

 

OUT

 

 

 

IN

 

OUT

 

T

OU

TPU

 

R

 

1

 

L

A

 

 

C

B

 

2 L

IN

PU

TS

 

L

R

 

 

3

 

UTP

UT

O

R

1

L

 

 

R 4 L R

 

 

 

S-42

2

 

-23

2/R

 

RS

 

 

 

 

 

 

 

REM

OTE

 

 

 

 

Remove (14)

Screws

Figure A-1 — Top cover removal

4. Lift the cover straight up and set it aside.

Relocating the ribbon cable and setting the jumper

If the MVP 104GX is currently configured for RS-232 communication, the ribbon cable must be relocated and the jumper must be reset for RS-422 communication. See figure A-2.

1. Disconnect the ribbon cable from the RS-232 receptacle, noting that the red stripe of the cable is positioned relative to pin #1 of the receptacle.

Both RS-232 and RS-422 receptacles are mounted with pin #1 located on the same side, relative to the circuit board.

2. Reconnect the ribbon cable to the RS-422 receptacle, as shown in

figure A-2. The red stripe of the ribbon cable must be positioned relative to pin #1 of the RS-422 receptacle.

A-2 MVP 104GX Reference Information

Page 48
Image 48
Extron electronic manual Reference Information, Configuring the MVP 104GX for RS-422, Removing the top cover