PROBLEM |
| PROBABLE CAUSES |
| CORRECTIVE ACTION |
| |||||
Drain valve or return | A. AIF board has failed. | Call your ASA for assistance. |
|
| ||||||
valve stays open. | B. | Actuator has failed. |
|
| ||||||
|
|
|
|
|
|
| ||||
|
|
|
| |||||||
|
|
| A. Verify that the power cord is fully | |||||||
|
|
|
| plugged in and the circuit breaker is | ||||||
Filter pump won’t start | A. Power cord is not plugged in or circuit |
| not tripped. |
|
|
|
|
| ||
B. If the motor | is | too | hot to | touch for | ||||||
or pump stops during |
| breaker is tripped. |
| more than a few seconds, the thermal | ||||||
B. Pump motor has overheated causing |
| |||||||||
filtering. |
| overload switch has probably tripped. | ||||||||
| the thermal overload switch to trip. |
| ||||||||
|
|
| Allow the motor to | cool at least 45 | ||||||
| C. Blockage in filter pump. |
| ||||||||
|
| minutes then press the Pump Reset | ||||||||
|
|
|
| |||||||
|
|
|
| Switch (see page |
|
| ||||
|
|
| C. Call your ASA for assistance. |
| ||||||
|
|
| A. Pull filter pan out and fully reinsert | |||||||
|
|
|
| into fryer. |
|
|
|
|
| |
| A. Filter pan is not fully set into fryer. | B. | Ensure the | filter pan magnet | is in | |||||
M3000 display shows |
| place and replace if missing. |
| |||||||
B. Missing filter pan magnet. |
|
| ||||||||
INSERT pan. | C. | If the filter | pan | magnet is | fully | |||||
C. Defective filter pan switch. | ||||||||||
|
| against the switch and computer | ||||||||
|
|
|
| |||||||
|
|
|
| continues | to | display | INSERT | |||
|
|
|
| pan, switch is possibly defective. | ||||||
| A. Oil level too low. | A. Ensure oil level is above the top oil | ||||||||
| B. Check that MIB board is not in |
| level sensor. |
|
|
|
| |||
|
| manual mode. | B. Ensure MIB board is in “A” | |||||||
Auto filtration won’t | C. | Check to see that the MIB cover is |
| automatic mode. | Power | cycle the | ||||
| not damaged and depressing the |
| fryer. |
|
|
|
|
| ||
start. |
|
|
|
|
|
|
| |||
| buttons. | C. Remove and replace cover and see if | ||||||||
|
| |||||||||
| D. AIF disable is set to yes, blue light |
| filtration will start. |
|
|
| ||||
|
| doesn’t light. | D. Set AIF disable in Level 1 to no. |
| ||||||
| E. | Filter relay has failed. | E. Call your ASA for assistance. |
| ||||||
|
|
| A. Remove the oil from the filter pan | |||||||
|
|
|
| and replace the filter pad, ensuring | ||||||
Filter Pump runs, but | A. Improperly installed or prepared filter |
| that the filter | screen is | in place | |||||
| under the pad. |
|
|
|
| |||||
| pan components. |
|
|
|
|
| ||||
oil return is very slow. |
|
| Verify, if using a pad, that the rough | |||||||
|
|
| ||||||||
|
|
|
| side is facing up. |
|
|
| |||
|
|
|
| Verify that | ||||||
|
|
|
| good condition on filter pan | ||||||
|
|
|
| connection fitting. |
|
|
| |||
M3000 display shows |
|
|
|
|
|
|
|
|
| |
OIL SENSOR | Oil sensor may have failed. | Call your ASA for assistance. |
|
| ||||||
FAIL. |
|
|
|
|
|
|
|
|
|
7.2.4Auto Top Off Problems
Problem | Probable Causes | Corrective Action |
Frypots top off cold. | Incorrect setpoint. | Ensure setpoint is correct. |
|
|
|
| A. Filter error exists. | A. Clear filter error properly. If |
| problem persists call your ASA for | |
One vat doesn’t top off. | B. Service required error exists | assistance. |
| C. Solenoid, pump, pin issue, RTD or | B. Call your ASA for assistance. |
| ATO issue. | C. Call your ASA for assistance. |