Frymaster BIGLA30 Problem, Probable Causes, Corrective Action, Call your ASA for assistance, Fail

Models: BIGLA30

1 88
Download 88 pages 5.79 Kb
Page 82
Image 82

PROBLEM

 

PROBABLE CAUSES

 

CORRECTIVE ACTION

 

Drain valve or return

A. AIF board has failed.

Call your ASA for assistance.

 

 

valve stays open.

B.

Actuator has failed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A. Verify that the power cord is fully

 

 

 

 

plugged in and the circuit breaker is

Filter pump won’t start

A. Power cord is not plugged in or circuit

 

not tripped.

 

 

 

 

 

B. If the motor

is

too

hot to

touch for

or pump stops during

 

breaker is tripped.

 

more than a few seconds, the thermal

B. Pump motor has overheated causing

 

filtering.

 

overload switch has probably tripped.

 

the thermal overload switch to trip.

 

 

 

 

Allow the motor to

cool at least 45

 

C. Blockage in filter pump.

 

 

 

minutes then press the Pump Reset

 

 

 

 

 

 

 

 

Switch (see page 5-7).

 

 

 

 

 

C. Call your ASA for assistance.

 

 

 

 

A. Pull filter pan out and fully reinsert

 

 

 

 

into fryer.

 

 

 

 

 

 

A. Filter pan is not fully set into fryer.

B.

Ensure the

filter pan magnet

is in

M3000 display shows

 

place and replace if missing.

 

B. Missing filter pan magnet.

 

 

INSERT pan.

C.

If the filter

pan

magnet is

fully

C. Defective filter pan switch.

 

 

against the switch and computer

 

 

 

 

 

 

 

 

continues

to

display

INSERT

 

 

 

 

pan, switch is possibly defective.

 

A. Oil level too low.

A. Ensure oil level is above the top oil

 

B. Check that MIB board is not in

 

level sensor.

 

 

 

 

 

 

manual mode.

B. Ensure MIB board is in “A”

Auto filtration won’t

C.

Check to see that the MIB cover is

 

automatic mode.

Power

cycle the

 

not damaged and depressing the

 

fryer.

 

 

 

 

 

start.

 

 

 

 

 

 

 

 

buttons.

C. Remove and replace cover and see if

 

 

 

D. AIF disable is set to yes, blue light

 

filtration will start.

 

 

 

 

 

doesn’t light.

D. Set AIF disable in Level 1 to no.

 

 

E.

Filter relay has failed.

E. Call your ASA for assistance.

 

 

 

 

A. Remove the oil from the filter pan

 

 

 

 

and replace the filter pad, ensuring

Filter Pump runs, but

A. Improperly installed or prepared filter

 

that the filter

screen is

in place

 

under the pad.

 

 

 

 

 

pan components.

 

 

 

 

 

oil return is very slow.

 

 

Verify, if using a pad, that the rough

 

 

 

 

 

 

 

side is facing up.

 

 

 

 

 

 

 

Verify that O-rings are present and in

 

 

 

 

good condition on filter pan

 

 

 

 

connection fitting.

 

 

 

M3000 display shows

 

 

 

 

 

 

 

 

 

OIL SENSOR

Oil sensor may have failed.

Call your ASA for assistance.

 

 

FAIL.

 

 

 

 

 

 

 

 

 

7.2.4Auto Top Off Problems

Problem

Probable Causes

Corrective Action

Frypots top off cold.

Incorrect setpoint.

Ensure setpoint is correct.

 

 

 

 

A. Filter error exists.

A. Clear filter error properly. If

 

problem persists call your ASA for

One vat doesn’t top off.

B. Service required error exists

assistance.

 

C. Solenoid, pump, pin issue, RTD or

B. Call your ASA for assistance.

 

ATO issue.

C. Call your ASA for assistance.

7-4

Page 82
Image 82
Frymaster BIGLA30 Problem, Probable Causes, Corrective Action, Call your ASA for assistance, level sensor, INSERT pan