Frymaster BIGLA30 warranty Position the melter

Models: BIGLA30

1 88
Download 88 pages 5.79 Kb
Page 86
Image 86
Figure 2: Position the melter.

BIGLA30 SERIES GEN II LOV™ GAS FRYER APPENDIX B: JIB Preparation with Solid Shortening Option

1.Open right door of fryer and remove brace in JIB cabinet.

2.Position melter in front of cabinet. Loosen bracket on left side of melter, if necessary, to ease placement in the cabinet.

3.Use the provided screws to attach the melter to existing holes in the interior rails of the fryer cabinet on both sides. See figures 1 and 2.

4.On the back side of the melter, attach the white two-pin connectors and plug in the black connector to the outlet box shown in figure 3.

5.Position the oil reservoir in the melter, sliding the oil pickup tube into the female receptacle. Position the front lid and the front of the melter. See figure 4.

Figure 2: Position the melter.

Orange button resets system after a low oil display.

Figure 1: Position the melter in the cabinet and attach with provided screws to the cabinet interior.

Figure 3: Attach the two-pin white connectors and plug the black connector into the utility box as shown.

Figure 4: The assembled melter is shown in position.

Melter ON/OFF switch.