•Ensure shortening melter is on.

BIGLA30 SERIES GEN II LOV™ GAS FRYER APPENDIX C: Solid Shortening Melter Use

Reset oil reservoir system

Ensure shortening melter is on.

Fill melter with shortening.

Allow 2-3 hours for solid shortening to melt. DO NOT attempt to use the top off system with unmelted oil in the top off system. The low oil reservoir light will come on if the fryer calls for oil before the shortening in the melter is liquid.

Once the shortening is fully melted, press and hold the orange reset button to turn off the light and reset the top off system.

Melter

ON/OFF switch

DO NOT ADD hot oil to the shortening melter. The temperature of the oil reservoir should not exceed 140°F. Add

small amounts of solid shortening to the reservoir to ensure it has sufficient oil to operate the top-off system.

For best results, DO NOT TURN OFF the solid shortening melter overnight.

The on/off switch for the melter is also used as a reset switch if the system’s high limit temperature is reached.