5.3 Host Commands

(43) READ LOG EXT (X'2F')

The READ LOG EXTEND command reads versatile log data. Versatile log data includes the Extended SMART Comprehensive Error log, the Extended SMART Self-test log, and the SMART Selective log. The effectiveness of the log types depends on customization. All types of versatile log data except Read Log Ext log page 10h are customizable. For the protocol concerning data transfers, see Section 5.4.

The number of the log to be read is specified as the Log address. For log data consisting of multiple sectors, a sector offset can be specified as an instruction so that data transfer starts from the specified sector. The number of sectors to be transferred is specified as the Sector count.

If an error occurs in the FP Queued protocol, Read Log Ext log page 10h containing the error information is transferred. This Read Log Ext log page can be read by specifying Sector offset = 00h, Sector count = 01h, and Log address = 10h. For the data format of Read Log Ext log page 10h, see Table 5.29.

If this command is not supported, or if an invalid value is specified for the Log address, Sector count, or Sector offset, the Aborted Command error occurs.

Error reporting conditions

(1)An error was detected during power-on processing (ST = 51h, ER = 04h).

(2)An error was detected during wake-up processing (in cases where wake-up processing is required before execution of this command)

(ST = 51h, ER = 04h).

(3)An error that cannot be corrected with ECC occurred (ST = 51h, ER = 40h).

(4)The sync byte indicating the beginning of a sector was not found (ST = 51h, ER = 01h).

(5)An invalid log sector address or invalid Sector count (number of sectors to be transferred) is specified (ST = 51h, ER = 04h).

(6)A SATA communication error occurred (ST = 51h, ER = 0Ch).