Interface

5.1.2 Signal interface regulation

5.1.2.1 Out of band signaling

During OOB signaling transmissions, the differential and common mode levels of the signal lines shall comply with the same electrical specifications as for in-band data transmission, specified as follows.

COMRESET/COMINIT

106.7 ns

320 ns

 

COMWAKE

106.7 ns

106.7 ns

 