5.3 Host Commands
Table 5.18 Data format of SMART Summary Error Log (1/2)
Byte |
|
| Item | |
|
|
|
|
|
00 | Version of this function |
|
| |
|
|
|
| |
01 | Pointer for the latest “Error Log Data Structure” | |||
|
|
|
| |
02 to 0D |
| Forth last command data structure | ||
|
|
|
| |
0E to 19 |
| Third last command data structure | ||
|
|
|
| |
1A to 25 |
| Second last command data structure | ||
|
|
|
| |
26 to 31 |
| Last command data structure | ||
|
|
|
|
|
32 |
|
|
| Device Control field value |
|
|
|
|
|
33 |
|
|
| Features field value |
|
|
|
|
|
34 |
|
|
| Sector Count field value |
|
|
|
|
|
35 |
|
|
| Sector Number field value |
|
| Command data |
|
|
36 |
|
| Cylinder Low field value | |
|
| structure |
|
|
37 |
|
| Cylinder High field value | |
|
|
| ||
|
|
|
|
|
38 |
|
|
| Drive/Head field value |
|
|
|
|
|
39 | Error log data |
|
| Command field value |
|
|
|
| |
|
| Elapsed time after the | ||
3A to 3D | structure |
|
| |
|
|
| sequence (unit: ms) | |
|
|
|
| |
|
|
|
|
|
3E |
|
|
| Reserved |
|
|
|
|
|
3F |
|
|
| Error field value |
|
|
|
|
|
40 |
|
|
| Sector Count field value |
|
|
|
|
|
41 |
|
|
| Sector Number field value |
|
|
|
|
|
42 |
|
|
| Cylinder Low field value |
|
| Error data structure |
|
|
43 |
|
| Cylinder High field value | |
|
|
|
|
|
44 |
|
|
| Drive/Head field value |
|
|
|
|
|
45 |
|
|
| Status field value |
|
|
|
|
|
46 to 58 |
|
|
| Vendor unique |
|
|
|
|
|
59 |
|
|
| State |
|
|
|
|
|
5A, 5B |
|
|
| |
|
|
|
|
|