3.3 Operation Mode Setup

 

 

 

 

 

ndd

-set /dev/fjgi 'instance'

value

(Instance number "value" of an applicable

 

 

 

 

interface is specified.)

ndd

-set

/dev/fjgi 'param1'

value

(Change 1 of a setup)

ndd

-set

/dev/fjgi 'param2'

value

(Change 2 of a setup)

 

:

 

 

:

 

ndd

-set /dev/fjgi 'adv_autoneg_cap'

N (Once let Auto-Negotiation be a different

 

 

 

 

value from the present condition.)

ndd

-set

/dev/fjgi 'adv_autoneg_cap'

M (Auto-Negotiation is returned to the

 

 

 

 

original value.)

example) While Auto-Negotiation had been enabled, when changing fjgi0 into 100Half (Autonego=1, link_sppd=100, link_mode=0) from a default state (Autonego=1, link_speed=1000, link_mode=1)

# ndd

-set

/dev/fjgi

'instance'

0

 

# ndd

-set

/dev/fjgi

'adv_1000fdx_cap'

0

# ndd

-set

/dev/fjgi

'adv_1000hdx_cap'

0

# ndd

-set

/dev/fjgi

'adv_100fdx_cap'

0

# ndd

-set

/dev/fjgi

'adv_autoneg_cap'

0

# ndd

-set

/dev/fjgi

'adv_autoneg_cap'

1

(Note) Please perform change and sending back of Auto-Negotiation at the end.

When setting change is reflected (an Auto-Negotiation value being subject to change):

ndd

-set

/dev/fjgi 'instance'

value

(Instance

number "value" of an

 

 

 

 

applicable interface is specified.)

ndd

-set

/dev/fjgi 'param1'

value

(Change 1

of a setup)

ndd

-set

/dev/fjgi 'param2'

value

(Change 2

of a setup)

 

:

 

 

:

 

ndd

-set /dev/fjgi 'adv_autoneg_cap'

N (Let Auto-Negotiation be a different value

 

 

 

 

from the

present condition.)

exapmle) When fjgi0 is changed into the state of 100Full where Auto-Negotiation was

disabled, from the state of 100Half (Autonego=1, link_sppd=100, link_mode=0) where Auto-Negotiation was enabled

# ndd

-set

/dev/fjgi

'instance'

0

 

#

ndd

-set

/dev/fjgi

'adv_100fdx_cap'

1

#

ndd

-set

/dev/fjgi

'adv_autoneg_cap'

0

(Note) Please make a change of Auto-Negotiation at the end.

● The following parameters can be used with the ndd command:

parameterstatusmeaning

 

 

 

?

Read only

Display parameter list

 

 

 

33