8.Pull the two tabs attached to the single edge contact (SEC) cartridge (visible after you remove the bracket—C in Figure 6) straight away from the system board. As you do, the cartridge disengages from the connector on the system board.

Tab on SEC cartridge

Retention module guide rails

SEC cartridge

Retention module guide rails

Tab on SEC cartridge

Processor heat sink

Figure 6: Removing a Processor

9.Slide the SEC cartridge straight away from the system board, out of the retention module. Put it on a piece of conductive foam and store it in an antistatic package.

10.Remove the replacement processor cartridge from its protective wrapping.

11.Orient the SEC cartridge so that the heat sink faces away from the center of the system board.

If you are installing a termination card assembly, orient it so that the side with the label faces toward the center of the system board.

34 Maintaining and Troubleshooting the Gateway ALR 9200 Server