23
FVR-C9S-2UX
4) Function setting method
Method Operation Procedure Display
1 PRG/RESET Press this key to switch to the
program setting mode.
60.0
F00
2 UP/DOWN Press UP key or DOWN key to
select function code
F01
3 FUNC/DATA Press this key to display function
code.
1
4 UP/DOWN Press UP key or DOWN key to
change function code data.
1
5 FUNC/DATA Press this key to store data.
F02
6Change other
function code PRG/RESET Press this key to cancel program
mode
60.0
C92-06