FVR-C9S-2UX

Function Code Tables

Function

Function

 

Date Code Range

Unit

Min.

Factory

Change

 

During

Code

 

Set.

Setting

 

 

 

 

Operation

 

 

 

 

 

 

 

 

F15

Motor Running

0

- 5 (code)

5

 

Yes

Sound

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F16

Fault Memory

The current and previous 3 fault events are displayed

No

in order of occurrence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F17

Data Initialization

0: Inactive

0

 

No

1: Reset to the initial value (value set at factory)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0: Inactive

 

 

 

 

 

F18

Retry

1: Active (Retry times fixed at 5, Retry starts in

0

 

No

 

 

.05s after trip)

 

 

 

 

 

F19

Motor

0

- 10

4

 

Yes

Characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F20

Jump Frequency

0

- 10Hz

Hz

1

3

 

Yes

Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F21

Jump Frequency 1

0

- 120Hz

Hz

1

0

 

Yes

 

 

 

 

 

 

 

 

 

F22

Jump Frequency 2

0

- 120 Hz

Hz

1

0

 

Yes

 

 

 

 

 

 

 

 

 

F23

Jump Frequency 3

0

- 120 Hz

Hz

1

0

 

Yes

 

 

 

 

 

 

 

 

F24

High Limiter

0

- 100%

%

1

100

Yes

 

 

 

 

 

 

 

 

 

F25

Low Limiter

0

- 100%

%

1

0

 

Yes

 

 

 

 

 

 

 

 

 

F26

Bias Setting

0

- 100%

%

1

0

 

Yes

 

 

 

 

 

 

 

 

F27

THR Terminal

0: External alarm input

0

 

No

Function

1: Multistep speed selection (X1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F28

BX Terminal

0: Motor coast-to-stop command input

0

 

No

Function

1: Multistep speed selection (X2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F29

Multistep Speed

0.0 - 120 Hz

Hz

1*

10.0

Hz

Yes

Setting 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F30

Multistep Speed

0.0 - 120 Hz

Hz

1*

20.0

Hz

Yes

Setting 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F31

Multistep Speed

0.0 - 120 Hz

Hz

1*

30.0

Hz

Yes

Setting 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F32

Meter Adjustment

0

- 99 (Full scale DC 6.5 - 10.5V)

1

85

 

Yes

 

 

 

 

 

 

 

 

F33

Meter Output

0: Output frequency monitor

1

0

 

Yes

selection

1: Output current monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 Frequency can be set in increments of 0.1 Hz within a range of 0.0 to 99.9 Hz, and can be set in increments of 1 Hz