Output frequency

FVR-C9S-2UX

F2 4 High Limiter F 2 5 Low Limiter

The upper and lower and lower limits of the output frequency can be set.

0Set as a percentage of the maximum frequency in increments of 1% within a range of 0 to 100%

1 0 0

If the value set for low limiter is higher than that set for the

100%

High

high limiter, the high limiter will take priority and the low

 

 

limiter

limiter will be ignored. Thus, operation will always be in

 

 

 

accordance with the high limiter value regardless of the

 

 

frequency setting.

Output

 

 

frequency

 

Low limiter

100%

Frequency setting

F 2 6 Bias Frequency

Outputs a bias frequency with respect to the analog frequency setting.

0Set as a percentage of the maximum frequency in increments of 1% within a range of 0 to 100%

1 0 0

F 2 7 THR Terminal Function

Bias

Frequency 100% setting

This function enables terminal THR to be used for two different functions by changing the data code as follows:

0External alarm input

1Multistep speed selection (X1)

This function data cannot be changed during operation. (Possible to change only in STOP mode).

F 2 8 BX Terminal Function

This function enables terminal BX to be used for two different functions by changing the data code as follows:

0Motor coast-to-stop command input

1Multistep speed selection (X2)

This function data cannot be changed during operation. (Possible to change only in STOP mode).