Chapter 4: Web-Based Management

Misc Configuration

In this page, you can change the default configuration for the 802.1x standard:

Figure 91: 802.1x Misc Configuration interface

c

This page includes the following fields:

OBJECT

DESCRIPTION

 

 

 

Used to define periods of time during which it will not attempt to

Quiet Period:

acquire a supplicant.

 

Default time is 60 seconds.

 

 

 

Set the period the port waits for retransmit next EAPOL PDU during an

TX Period:

authentication session.

 

Default value is 30 seconds.

 

 

 

Set the period of time the switch waits for a supplicant response to an

Supplicant Timeout:

EAP request.

 

Default value is 30 seconds.

 

 

 

Set the period of time the switch waits for a server response to an

Server Timeout:

authentication request.

 

Default value is 30 seconds.

 

 

 

Set the number of authentication that must time-out before

Max Requests:

authentication fails and the authentication session ends.

 

Default value is 2 times.

 

 

 

Set the period of time which clients connected must be re-

Reauth period:

authenticated.

 

Default value is 3600 seconds.

 

 