Installation Instructions

J

Making the L.P. Gas Conversion

J1 Know what needs to be converted

The pressure regulator and the burner orifices are set for natural gas. To use liquid propane gas, the regulator and burner orifices must be converted.

The L.P. orifice spuds for the cooktop burners can be located within a bracket located behind the storage drawer of this unit.

Do not operate the cooktop or oven burners of this range when using L.P. (bottled) gas before converting the

pressure regulator and burner orifices for L.P. gas use. Failure to do so could cause high flames and toxic fumes which can result in serious injury.

WARNING: This conversion must be performed by a qualified installer or gas supplier in accordance with the manufacturer's instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion.

To adjust your range for use with L.P. gas, follow these instructions:

1.Disconnect all electrical power at the main circuit breaker or fuse box.

2.Shut off the gas supply to the range by closing the manual shut-off valve.

J2 AdjustingRegulator the Pressure

CAUTION: If you are using L.P. (bottled) gas, all the adjustments described in the following steps must be made before you

make any burner adjustments.

CAP

GASKET

 

LP

NAT

 

 

 

NAT

LP

 

 

 

 

 

SPRING

LP

NAT

RETAINER

NAT

LP

 

NAT.

L.P./PROPANE

POSITION

POSITION

 

 

 

OFF FOR

 

 

DOWN

 

PRESSURE REGULATOR

a.Remove the storage drawer.

b.Find the pressure regulator by reaching through the storage compartment and the opening at the back of the range.

c.Unscrew the cap.

d.Carefully look at the spring retainer to locate the NAT or LP position.

e.Place your thumb against the flat side of the spring retainer and press down to remove the retainer.

f.Turn the spring retainer over so that L.P. is showing on the bottom.

g.Snap the retainer back into position and

retighten the cap back onto the regulator.