Installation o@ons

Installation rules

Venting ruzes

The Monogram Component Cooktop System offers the - Updraft components can be vented according to

ultimate

in design

and

cooking

flexibility,

with

modular

normal

exhausting

methods.

 

 

 

 

 

 

 

 

 

 

cooktops

and accessories,

 

providing

a variety

of cooking

“ The downdraft

 

grill or vent

blower

maybe

oriented in

technologies

to meet

the needs

of the most

discerning

two directions—toward

the rear or down

as required.

cook.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blower

can

be

mounted to left

or

right

side

of vent

“ Each component

 

can

be installed

in many

orientations

housing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in the countertop.

 

 

 

 

 

 

 

 

 

 

 

 

 

. Gas and

halogen

 

components

 

are only

3-1 /4”

deep,

“ Both gas and electric

 

components

can be combined

allowing

room

for

a drawer

beneath

 

in many

cabinet

within

the

cooking

configurations:

 

 

 

 

 

 

styles.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– Multiple

electric

components

 

can operate

from a

. Optional

Remote

Control

Accessory

 

Kit for downdraft

single

junction

box,

if local

codes

permit.

 

 

 

vent component

 

 

is available

for use when

remote

– Multiple

gas components

can

operate

from

a

control

of blower

is desired.

 

 

 

 

 

 

 

 

 

 

manifold, as permitted by local codes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

. Always choose cabinetry that enhances installation

“ Always consider option to shorten drawer for gas inlet

process.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

clearance. (To determine location of gas pipe, refer to

. Always anticipate that cabinet modification maybe

cutout illustration in “Design Information, Dimensions

required for European or other custom cabinetry.

and clearances.

 

)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“ Always preplan electrical and gas connections to be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

. Gas components cannot be converted to liquid

 

accessible

at installation

time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

propane

gas operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

. Always consider distance to power supply, cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

lengths and bending restrictions before cutting holes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

. Always

preplan

component

locations

before

installa-

. If possible,

don’t

 

cut holes

for

remote

 

mount

vent

tion; determine

need

 

to reorient

downdraft

 

blower

control

and

ductwork

locations

until

components

are

discharge

direction,

or if blower

will need

to be

on-site,

with

countertop

in place,

and all preplanning

relocated

to opposite

 

side of vent housing.

(Down-

locations

are

confirmed.

 

 

 

 

 

 

 

 

 

 

 

draft unit

is shipped

with blower

mounted

on

left side

. Every downdraft

 

 

vent and

downdraft

 

grill

cooktop

of housing.

)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

must have a complete,

separate

duct

run. Ducts

from

“ Always

consider

how

 

cooktop

(and

grease

collection

different

downdraft

units

cannot

be

combined.

 

 

jars) or downdraft

vent housing

affect

cabinet

type

. Do NOT

install

 

a downdraft

vent

behind

a cooktop,

selection (especially

drawers).

 

 

 

 

 

 

 

 

UNLESS

you

use

accessory

kit 3-AO1 O to move

the

. Always

provide

clearance

 

for remote

mount

vent

control

to the front

of

the

cabinet.

 

 

 

 

 

 

 

 

control

wiring box

when

installing

on

cabinet

 

face

. Do NOT

install

 

a gas or grill

cooktop

 

where

the

knobs

between

components,

 

or other locations.

 

 

 

 

are between

 

the

 

heated

area and

the downdraft

vent.

. Always anticipate base cabinet storage arrangements to . Do NOT install an updraft grill cooktop next to a

accommodate downdraft blower and duct locations. downdraft vent.

. Never vent a cooktop into an interior space–always to outdoors.

. Do not install an updraft grill unless overhead vent is 300 CFM or more.

39

Page 39
Image 39
GE Monogram ZGW124, ZEW154, ZEW155, ZEW165, ZEW175, ZEW164, ZEW145, ZGW125 Installation o@ons Installation rules Venting ruzes

ZEW145, ZEW165, ZEW164, ZEW175, ZGW125 specifications

The GE Monogram line of refrigeration products is known for its blend of innovative technology, luxurious design, and exceptional performance. Among their offerings are the Monogram ZEW155, ZEW154, ZGW124, ZGW125, and ZEW175 models, each providing unique features and characteristics tailored to meet the needs of modern kitchens.

The GE Monogram ZEW155 is a built-in under-counter wine cooler that showcases both elegance and functionality. With a capacity for up to 24 bottles, it features dual temperature zones allowing wine enthusiasts to store both red and white wines at the optimal temperatures. The stainless steel construction is not only durable but also blends seamlessly into kitchen cabinetry, while the UV-resistant glass door helps protect wine from harmful light exposure.

Similarly, the ZEW154 offers a sleek design with a capacity to hold up to 33 bottles. Its state-of-the-art temperature management system ensures precise cooling, providing ideal storage conditions to maintain the integrity of the wine. Additionally, the integrated LED lighting illuminates the interior without generating excessive heat, enhancing the display of stored bottles.

Moving onto the ZGW124 and ZGW125, these models exemplify versatility in a compact design. The ZGW124 is an under-counter refrigerator that offers a generous capacity of 5.6 cubic feet, while the ZGW125 provides a slightly larger space of 7 cubic feet. Both models are equipped with adjustable shelves, making it easy to customize storage for various items. The advanced cooling technology ensures even temperature distribution, preventing hotspots and preserving food freshness.

The ZEW175 stands out with its spacious 7.5 cubic feet capacity and dual temperature zones specifically designed for wine. This model is particularly well-suited for those who appreciate the subtleties of wine storage, with advanced features like vibration dampening technology that minimizes disturbances to wine bottles. The lead-free glass door also provides a clear view of stored items while protecting them from UV rays.

Each of these GE Monogram models is designed with the modern consumer in mind, incorporating energy-efficient technologies that reduce energy consumption while maintaining optimal performance. With thoughtful design elements and advanced refrigeration technologies, the GE Monogram ZEW155, ZEW154, ZGW124, ZGW125, and ZEW175 redefine the standards of luxury in home refrigeration solutions, making them quintessential choices for discerning homeowners.