7
Step
Installation
(continued)
Relocateblowe?-
Dfagram 551
After duct location isdetermined, it may be necessary to
relocate blower to opposite side of vent housing.
Follow previous instructions to remove blower side
plate and blower.
oRemove filter guide from inside vent housing with
Phillips screwdriver.
Relocate filter guide to opposite side of vent housing.
.Replace screws and tighten with Phillips screwdriver.
Relocate blower to opposite side of vent housing with
outlet oriented to rear or down as required.
.Replace and tighten removed nuts with a7/1 6“ socket ~
wrench from inside vent housing. Diagram 55.?
.Replace blower side plate and secure 4nuts using
5/1 6“ nut driver.
.Reposition filter inside throat of vent housing.
8Connect
Step gas
.
.
.
Install supplied pressure regulator in gas line asclose
to cooktop inlet aspossible, making allowances for
ventilation ducting as necessary.
Make sure regulator isinstalled in correct position.
(Note flow direction arrow on underside of regulator.)
Install manual shut-off valve in gas line in an easily
accessible location, asclose to pipe stub as possible,
making allowances for ventilation ducting. Be sure you
know how and where to shut off the gas supply to
cooktop.
Appropriate flare union adaptors are required at each
end of flexible connector.
Turn on gas: check for leaks using aliquid leak
detector at alljoints in the system (the pressure test
fitting is located on the pressure regulator).
Note: Instead of using solid
piping to connect to pressure
regulator, an approved flexible
metal appliance connector may
be used between the shut-off
and the pressure regulator, if
local codes permit.
Caution z
/. Donot use aflame to check for
Y/gas’eaks’
nSolid Piping
or Flexible
I!!4Connector
&
@n
Shut-Off
Valve
PipeStub
fagram553
55